PRECISION EVIDENTIARY ALCOHOL ANALYZER IN THE USE BY ROAD SERVICES (POLICE) AND HEALTHCARE INSTITUTIONS
Evidentiary professional alcohol analyzer for fast and precision testing with the ability to capture results using two types of sensors.
Dräger Alñotest®9510 Standard IR+EC
- Compliance with the requirements of ÎIML R 126:1998 «Evidential breath analyzers (O²ML R 126, ed³t³on 1998, ²DT)», ÎIML R 126:2012 «Evidential breath analyzers (O²ML R 126, ed³t³on 2012, ²DT)», DSTU ÎIML R 126:2014 «Äîêàçîâ³ àíàë³çàòîðè âèäèõóâàíîãî ïîâ³òðÿ (O²ML R 126, ed³t³on 2012, ²DT)»;
- Compliance with the Technical Regulation of Legally Regulated Measuring Instruments, approved by the CMU Decree No. 94 of 13.01.2016;
- Compliance with the Technical Regulations on medical products, approved by the CMU Decree No. 753 of 02.10.2013;
- The device has a color LCD touch screen with high resolution. A large screen with a virtual keyboard function and clear full-text messages provides simplicity of management.
- Dräger Alñotest®9510 Standard IR+EC has many interfaces. This allows you to easily connect the device to a remote computer or devices such as printer, modem and Ethernet.
- When carrying out a quantitative and qualitative analysis of alcohol in the exhaled air, the Dräger Alñotest®9510 Standard IR+EC uses two different independent sensors: infrared and electrochemical.
- To check the zero calibration of the infrared sensor, an independent infrared analysis of the ambient air in the absorption chamber is performed before each alcohol test.
- Thanks to the robust housing of the Dräger Alñotest®9510 Standard IR+EC is ideally suited for harsh environments, for mobile or stationary use.
- The Dräger Alñotest®9510 Standard IR+EC can be positioned and used in a horizontal or vertical position by switching the screen in the appropriate mode.
- The built-in printer allows you to print all relevant data, for example, date, time, measurement result, units and instrument number as a protocol. The device also allows you to print all measurements on an external or integrated printer, as well as entered data and diagrams.
- Operating conditions during operation: from 0°Ñ to + 40°Ñ at relative humidity from 30% to 90%, atmospheric pressure from 850 to 1060 hPa, height of the location is maximum 3000 m.
- Conditions during storage: temperature from -20°C to + 70°C (more than 40°C only for some hours) at a relative humidity of 10 to 90%, atmospheric pressure from 700 to 1300 hPa.
- Memory: not less than 1000 last tests;
- Ways to enter text information into the device's memory: display (touch screen), Keyboard Mini QWERTY keyboard (USB);
- The overall dimensions are about 325 x 250 x 55/185 mm (W x H x D) and weight 6.9 kg (without keyboard).
- Power supply: from 110 V to 240 V, from 50 to 60 Hz or from a 12 V DC source (from 10.5 to 15.5 V).
- Power consumption: at the stage of heating up about 70 W, in the standby mode <15 W.
- Main fuse TH / 250 V; 0.63 A, 2 pcs.
- Full version of the menu in Ukrainian.
- Discreteness of results 0,01 ‰.
- Measurement range:
- mass concentration of alcohol in the exhaled air - from 0 to 3 mg / l (ratio of the mass of ethanol in the exhaled air to the volume of this air, reduced to a temperature of 34 °C and pressure of 1013 hPa);
- the mass concentration of alcohol in the blood - from 0 to 6 ‰ (the ratio of the mass of ethanol in the blood to the volume of blood at 20 ° C).
- Limits of the permissible error for type checking, primary verification and verification after repair:
- for the mass concentration of alcohol in the exhaled air:
- absolute error (Δ): ± 0,02 mg / l - in the range from 0 to 0,4 mg / l;
- relative error (δ): ± 5% - in the range from 0.4 to 2.0 mg / l;
- absolute error (Δ): ± (0,5R - 0,9) mg / l - in the range over 2,0 mg / l (R is the reference value of the mass concentration of alcohol).
- For the mass concentration of alcohol in the blood:
- absolute error (Δ): ± 0,04 ‰ - in the range from 0 to 0,8 ‰;
- relative error (δ): ± 5% - in the range from 0.8 to 4.0 ‰;
- absolute error (Δ): ± (0,5R - 1,8) ‰ - in the range above 4,0 ‰ (R is the reference value of the mass concentration of alcohol).
- Limits of the permissible error in operation:
• for the mass concentration of alcohol in the exhaled air:
- absolute error (Δ): ± 0,03 mg / l - in the range from 0 to 0,4 mg / l;
- relative error (δ): ± 7.5% - in the range from 0.4 to 2.0 mg / l;
- absolute error (Δ): ± (0,75R - 1,35) mg / l - in the range above 2,0 mg / l (R is the reference value of the mass concentration of alcohol).
- For the mass concentration of alcohol in the blood:
- absolute error (Δ): ± 0,06 ‰ - in the range from 0 to 0,8 ‰;
- relative error (δ): ± 7.5% - in the range from 0.8 to 4.0 ‰;
- absolute error (Δ): ± (0.75R - 2.7) ‰ - in the range above 4.0 ‰ (R is the reference value of the mass concentration of alcohol).
STUDY OF CONSUMER DEMAND!
Upon access to the certified Dräger service center of Saturn® Data International, the execution of the operations "Grading" and "Checking" of the instruments is carried out at government rates, after the operation "Check" the client is provided with a Certificate of verification of the working means of the state-of-the-art measuring equipment, as well as diagnostics with providing the necessary recommendations and servicing the devices within the package "Complex". If these operations are performed within the package "Complex" at least 1 time in 12 months post-warranty repair is carried out with special discounts.
Regulations:
|