DA Z22 —EXTERNAL DIGITAL INTERCOM STATION FOR EXPLOSIV AREAS 2/22

 

External digital intercom stations DA-Z22 series are especially designed for application in highly explosive areas 2/22 as defined by the European standard IEC 60079-15 and IEC 61241. 

Type of protection: 
Ĺő ďŔ ďŃ II Ň4 DIP A22 ŇŔ Ň4
Explanations:
nA : no electromagnetic emission
nC : protected contacts

II : for gas-explosive areas
T4: surface temperature > 135°C
DIP A 22: deflagrating mixture protection

Components:

  • Reinforced glass-fiber polyester housing, hardly inflammable, black color
  • Front panel assembly with microphone and loudspeaker
  • 6 DSA electronic unit

Features:

  • Modular design for easy maintenance
  • Rotary switches for direct communication links
  • Call or busy signal by light emitting diodes
  • Noise compensated microphone
  • Adjustable microphone sensitivity and volume
  • Potential-free relay point

Options:

  • Booster amplifier 25 DVX01.

 

Main characteristics

DA Z22 Mechanical data:

Dimensions

450 x 134 x 183 mm

Cable glands

2 x Ě25+ 2 x Ě20

Weight

~4,5 kg

 

DA Z22 Electrical data: 

 

Operating voltage range

48 — 72 VDC

Quiescent & max. current consumption

20 mA / 100 mA

Loudspeaker output

15 W

Loudspeaker resistance

8 Ohm

Frequency range

300 — 3400 Hz

Sound pressure level (30 cm distance)

115 dB

 

Electrical data of booster amplifier 25 DVX 01: 

 

Operating voltage range

48 — 72 VDC

Quiescent & max. current consumption

20 mA / 850 mA

Output power

25 W/400 Ohm

Loudspeaker resistance

8 Ohm

 

Service conditions: 

 

Ambient temperature

-40 — +70°Ń (+85°C)

Protection degree

IP 65

EMC

EN 50081-2,
EN 61000-6-2

 

 

Photo gallery