Intercom stations DX series are especially designed for application in hazardous areas as defined by the European standard EN 0014.
Approval: PTB 00 ATEX 2137
Type of protection: EEX de ib IIC T4
Explanations:
EEX: according to DIN EN 50014;
d: flameproof;
å: increased safety
ib: intrinsically safe category b;
IIC: most ignitable gas group
T4: surface temperature > 135°C
Components:
- Fiber reinforced polyester housing, hardly inflammable, color RAL 3000 (red), protection class IP 65
- All sparking electronic components, 6DSX02 units installed in explosion-proof metal enclosure
- Protection for module 1DEX 01
- Intrinsically safe electronics unit 6DSX02
Features:
- Modular design for easy maintenance
- Rotary switches for direct communication links
- Call or busy signal by light emitting diodes
- Noise compensated microphone
- Adjustable microphone sensitivity and volume
- Potential-free relay point
Options:
- Booster amplifier 25 DVX01
Main characteristics
DX 003-ATEX Mechanical data:
Dimensions
|
450 x 134 x 183 mm
|
Cable glands
|
2 x Ì20 + 1 x Ì25
|
Weight
|
~6,5 kg
|
DX 003-ATEX Electrical data:
Operating voltage range
|
48 — 72 VDC
|
Quiescent & max. Current consumption
|
20 mA / 70 mA
|
Loudspeaker output
|
15 W
|
Loudspeaker resistance
|
8 Ohm
|
Frequency range
|
300 — 3400 Hz
|
Sound pressure level
|
106 dB
|
Relay contact
|
1À, 90 VDC, 30 W
|
Electrical data of booster amplifier 25 DVX 01:
Operating voltage range
|
48 — 72 VDC
|
Quiescent & max. current consumption
|
20 mA / 850 mA
|
Output power
|
25 W
|
Service conditions:
Ambient temperature
|
- 40 — +55°Ñ
|
Protection degree
|
IP 65
|
EMC
|
EN 50081-2, EN 61000-6-
|
Max. ambient noise level
|
100 dB
|
|